5 Installation

5.1 Mechanical installation

  • The single chamber press EK700 or single chamber press EK800 has to stand on an even floor.
  • Adjust all feet, so that the machine is in level and check this by using a spirit level.

It's not allowed to work with the press in an hazardous location.

  • Check the machine according chapter 5.4

5.2 Electrical installation

The single chamber press EK700 or single chamber press EK800 (4 ton machine) runs on a single phases power supply 230V with a standard SCHUKO- plug for a socket

  • Check the sockets fusing according the total power consumption of the press (chapter 1.3.2 and 1.3.3).
  • Run the connection cord over the floor ground in thus way, nobody can trip over it

The single chamber press EK700 or single chamber press EK800 (6 ton machine) runs on a three phases power supply with a standard CEE-400V/16A plug for a socket or 200 V/16A without a plug for a socket

  • Check the sockets fusing according the total power consumption of the press (chapter 1.3.2 and 1.3.3).
  • Run the connection cord over the floor ground in thus way, nobody can trip over it

The connection hast to be performed by trained and expert personnel according to electrical safety regulations!
Make sure that the electrical connection has a positive phase sequence