1. When a PICK UP CUP is too away from the sheets.
→ Turn right the feeding height adjustment knob as to raise the feeding device.
Then, try again to raise the feeding table.
A height that the Pick-Up Cup lifts a sheet is recommended to 20mm.
2. When Air pressure from the VACUUM PUMP is few.
→ It is recommended to keep an original setting conditions.
But it could be a little bit decreased the air pressure.
Turn right the vacuum pump pressure adjustmnet handle as to increase.
3. When the vacuum pump is defective.
→ Relace the vacuum pump. Please contact the supplier.
4. When the Input Pressure's phase on the vacuum pump was changed and the pump is running in revrse.
→ Change the Input Pressure's Phase.
Immediaely stop the operation. And contact the supplier.
5. When the sheet curling is too much toward to the bottom.
→ Adjust the sheets can be at a same level as shown in right picture.
|